New analysis reveals challenges in using extracellular vesicles as blood-based biomarkers

Extracellular vesicles (EVs) are tiny membrane-bound particles released by cells that carry proteins, RNA, and other molecules. Because they circulate in the bloodstream and can reflect the condition of their cells of origin, researchers are increasingly interested in using them as biomarkers for diagnosing diseases, monitoring treatment responses, and understanding biological processes. However, separating EVs from other components in blood plasma remains a significant challenge.

Researchers at NOVA Medical School, Universidade NOVA de Lisboa in Portugal have conducted a large-scale analysis revealing that many proteins commonly associated with plasma extracellular vesicles may not originate from the vesicles themselves. Published in Communications Biology, the research highlights important challenges in EV isolation and provides a new framework for interpreting their protein composition.

Analyzing more than 500 extracellular vesicle proteomes

The researchers analyzed 515 human plasma EV proteomes collected from 20 previously published investigations. A proteome represents the complete collection of proteins detected in a sample. By comparing these datasets, the team sought to identify proteins consistently associated with plasma EV preparations and determine their biological origins.

The analysis identified 344 proteins detected in more than half of the samples. However, many of these proteins were not necessarily components of extracellular vesicles. Instead, the researchers found that much of the protein signal could be explained by three major sources: proteins attaching to vesicle surfaces, vesicles released by activated platelets during blood collection, and other biological molecules isolated alongside EVs.

These findings suggest that conventional EV isolation techniques may capture substantial amounts of material that do not reflect the original contents of circulating vesicles.

Deconvolution of the plasma EV core proteome and anchor proteins into eight distinct biological modules

Fig. 7: Deconvolution of the plasma EV core proteome and anchor proteins into eight distinct biological modules.

Pairwise correlation analysis of the core proteome reveals eight co-isolating protein clusters. Biological annotation was performed using the anchor proteins defined in Table 1. The side annotation bar indicates the specific biological category of individual proteins. Cluster-level color coding represents the predominant biological category identified within that module (determined by the most frequent anchor protein assignment); clusters lacking a dominant category are assigned a distinct color. Cluster labels indicate the Cluster ID and the mean correlation coefficient (r) of the module. Heatmap intensity represents the pairwise Pearson correlation between proteins.

How proteins attach to extracellular vesicles

One of the most significant findings involves the formation of a protein corona, a layer of proteins that accumulates on the surface of a particle.

The researchers discovered that the protein composition of plasma EV preparations closely resembled the protein coronas that form around synthetic nanoparticles. This similarity suggests that electrical interactions between proteins and vesicle surfaces, along with the abundance of proteins in plasma, strongly influence which proteins are recovered during EV isolation.

As a result, some proteins identified as EV-associated biomarkers may actually be attached to the outside of vesicles rather than packaged within them. This distinction is important because researchers attempting to identify disease-specific biomarkers need to understand whether detected proteins reflect cellular activity or interactions occurring in blood plasma.

Blood collection can influence EV measurements

The analysis also revealed that platelet activation during blood collection may significantly affect EV protein profiles. Platelets are blood components involved in clotting, and they can release extracellular vesicles when activated.

The researchers found that the protein signatures of plasma EV preparations closely resembled those of platelet-derived vesicles produced following thrombin stimulation. This suggests that some EVs detected in blood samples may be generated during blood collection and processing rather than circulating naturally in the bloodstream.

These findings emphasize the importance of standardized blood collection, sample handling, and EV isolation procedures. Differences in these steps could influence experimental results and make comparisons between laboratories more difficult.

Improving extracellular vesicle biomarker research

To address these challenges, the researchers developed a computational framework that separates plasma EV protein signatures into distinct biological components. Their analysis identified eight protein modules representing different sources, including platelet-derived vesicles, plasma proteins, immune-related complexes, and other co-isolated materials.

This approach could help scientists distinguish genuine vesicle-associated signals from background proteins and artifacts introduced during sample preparation. Rather than treating all proteins recovered from EV preparations as equally informative, researchers could use these classifications to better evaluate the biological origins of potential biomarkers.

The findings have important implications for liquid biopsy development, where blood samples are analyzed to detect disease-associated molecular changes. Improving the accuracy of EV protein profiling could support more reliable biomarker discovery and help reduce misleading results caused by sample contamination.

Toward more reliable EV-based diagnostics

This research demonstrates that the protein composition of plasma extracellular vesicle preparations is more complex than previously assumed. Many consistently detected proteins appear to result from surface interactions, platelet activation, or the co-isolation of other blood components rather than from the original cargo of circulating EVs.

By identifying these different sources and introducing a framework for separating their contributions, the researchers provide a foundation for improving EV characterization and proteomic analysis. More accurate interpretation of extracellular vesicle proteins could ultimately strengthen their usefulness in disease detection, precision medicine, and the development of blood-based diagnostic tests.

Carvalho AS, Falcón-Pérez JM, Beck HC, Matthiesen R. (2026) Analysis of 515 human proteomes defines plasma extracellular vesicle core composition, corona and coisolated networks. Communications Biology 9: 1402. [article]