Researchers develop advanced nanoparticle technology leveraging extracellular vesicles for rapid detection of heart disease and brain cancer

Researchers at the University of Notre Dame have developed a novel, automated device capable of diagnosing glioblastoma, a fast-growing and incurable brain cancer, in less than an hour. The average glioblastoma patient survives 12-18 months after diagnosis.

The crux of the diagnostic is a biochip that uses electrokinetic technology to detect biomarkers, or active Epidermal Growth Factor Receptors (EGFRs), which are overexpressed in certain cancers such as glioblastoma and found in extracellular vesicles.

“Extracellular vesicles or exosomes are unique nanoparticles secreted by cells. They are big — 10 to 50 times bigger than a molecule — and they have a weak charge. Our technology was specifically designed for these nanoparticles, using their features to our advantage,” said Hsueh-Chia Chang, the Bayer Professor of Chemical and Biomolecular Engineering at Notre Dame and lead author of the study about the diagnostic published in Communications Biology.

The challenge for researchers was two-fold: to develop a process that could distinguish between active and non-active EGFRs, and create a diagnostic technology that was sensitive yet selective in detecting active EGFRs on extracellular vesicles from blood samples.

To do this, researchers created a biochip that uses an inexpensive, electrokinetic sensor about the size of a ball in a ballpoint pen. Due to the size of the extracellular vesicles, antibodies on the sensor can form multiple bonds to the same extracellular vesicle. This method significantly enhances the sensitivity and selectivity of the diagnostic.

Then synthetic silica nanoparticles “report” the presence of active EGFRs on the captured extracellular vesicles, while bringing a high negative charge. When extracellular vesicles with active EGFRs are present, a voltage shift can be seen, indicating the presence of glioblastoma in the patient.

This charge-sensing strategy minimizes interference common in current sensor technologies that use electrochemical reactions or fluorescence.

“Our electrokinetic sensor allows us to do things other diagnostics cannot,” said Satyajyoti Senapati, a research associate professor of chemical and biomolecular engineering at Notre Dame and co-author of the study. “We can directly load blood without any pretreatment to isolate the extracellular vesicles because our sensor is not affected by other particles or molecules. It shows low noise and makes ours more sensitive for disease detection than other technologies.”

In total, the device includes three parts: an automation interface, a prototype of a portable machine that administers materials to run the test and the biochip. Each test requires a new biochip, but the automation interface and prototype are reusable.

Sensing method utilizes highly negative zeta potential of silica reporters to produce a signal

Fig. 1

a General schematic and overall workflow of our platform. First, samples containing EVs are incubated, washed, incubated with silica reporters, and washed again. The platform consists of an anion exchange membrane that only allows counter ions to pass through and exhibits three distinct regimes in the current-voltage response. b Current-voltage response of an Anion Exchange Membrane: EV does not produce any shift in the overlimiting region, while silica reporters do produce a shift after forming a sandwich due to their highly negative charge. c Automation algorithm of our platform with an automation interface, prototype, and biochip showing the housing of AEM. d Voltage shift for anti-CD63 capture and anti-CD63 reporter (both monoclonal and of the same clone) that target a specific epitope of CD63 – binding only to species that contain at least two unique copies of CD63 at different concentration of sEVs measured in triplicates e Highly negative zeta potential of silica particles compared to EVs from two cell cultures and pooled healthy plasma (all done in triplicates except silica where there are nine replicates). All the error bars are one standard deviation.

Running one test takes under an hour, requiring only 100 microliters of blood. Each biochip costs less than $2 in materials to manufacture.

Although this diagnostic device was developed for glioblastoma, the researchers say it can be adapted for other types of biological nanoparticles. This opens up the possibility for the technology to detect a number of different biomarkers for other diseases. Chang said the team is exploring the technology for diagnosing pancreatic cancer and potentially other disorders such as cardiovascular disease, dementia and epilepsy.

“Our technique is not specific to glioblastoma, but it was particularly appropriate to start with it because of how deadly it is and the lack of early screening tests available,” Chang said. “Our hope is that if early detection is more feasible, then there is an increased chance of survival.”

The research is a collaborative effort involving several institutions, including Vanderbilt University and the Olivia Newton-John Cancer Research Institute in Australia. Dr. Sonu Kumar, the primary researcher, and Dr. Hsueh-Chia Chang, the lead investigator at Notre Dame, spearheaded this development.

Source – Notre Dame University

Maniya NH, Kumar S, Franklin JL, Higginbotham JN, Scott AM, Gan HK, Coffey RJ, Senapati S, Chang HC. (2024) An anion exchange membrane sensor detects EGFR and its activity state in plasma CD63 extracellular vesicles from patients with glioblastoma. Commun Biol 7(1):677. [article]